Wikiposts
Search
Tech Log The very best in practical technical discussion on the web

A320:hyd

Thread Tools
 
Search this Thread
 
Old 5th Jan 2007, 13:53
  #1 (permalink)  
Thread Starter
 
Join Date: Jul 2006
Location: 'tween posts
Posts: 197
Likes: 0
Received 0 Likes on 0 Posts
A320:hyd

Hello everyone,
Trying to come to grips with A320 hyd sys.
wonder why the B sys pump sw is guarded on the over head panel

can any one help? appriciate all inputs,thanks!
gearpins is offline  
Old 5th Jan 2007, 16:25
  #2 (permalink)  
 
Join Date: Mar 2005
Location: England
Posts: 730
Likes: 0
Received 0 Likes on 0 Posts
Because blue system hydraulics is automated to energise when configuration requires it.
The switch on the overhead panel is to allow for manual operation when aircraft is in a config that it wouldn't come on automatically (ie maintenance).
Fargoo is offline  
Old 5th Jan 2007, 16:39
  #3 (permalink)  
 
Join Date: Dec 2006
Location: States
Posts: 2
Likes: 0
Received 0 Likes on 0 Posts
B sys

Blue has no backup like Y and G sys. Mistakenly selected off could cause some heartburn. So like most of the system's, if the switch is critical or ir-revokeable, put a guard on it that requires confirmation of the action.

Or as Sam tells me...it's a follow through from the A300's system.
oogrooq is offline  
Old 5th Jan 2007, 20:42
  #4 (permalink)  
 
Join Date: Oct 2006
Location: Finland
Posts: 22
Likes: 0
Received 0 Likes on 0 Posts
The guarded pushbutton for blue pump on the overhead maintenance panel does not have an OFF function.
The button says blue pump ovrd, meaning that the button overrides the automatic function and as Fargoo pointed out, it can be used for maintenance purposes, for example.
Nelli is offline  
Old 5th Jan 2007, 21:27
  #5 (permalink)  

Dog Tired
 
Join Date: Oct 2001
Location: uk
Posts: 1,688
Likes: 0
Received 1 Like on 1 Post
Originally Posted by Fargoo
Because blue system hydraulics is automated to energise when configuration requires it.
Rubbish. It is on all the time. Read the books.

Sorry; should have added:
I believe it is guarded because there will be nothing to replace it if you (mistakenly) turn the elec pump off. If you turn Y or G Eng pump off, the PTU will provide.

Last edited by fantom; 5th Jan 2007 at 21:38.
fantom is offline  
Old 5th Jan 2007, 22:28
  #6 (permalink)  
Thread Starter
 
Join Date: Jul 2006
Location: 'tween posts
Posts: 197
Likes: 0
Received 0 Likes on 0 Posts
would the rat get deployed if you switch off the Blue system pump?.
(I am refering to the switch on the Hyd panel and not the Blue Pump OVRD switch on the maint panel)
gearpins is offline  
Old 5th Jan 2007, 22:41
  #7 (permalink)  
 
Join Date: Jan 1999
Location: uk
Posts: 20
Likes: 0
Received 0 Likes on 0 Posts
fantom, re-read the book Fargoo is right.
gearpins, No.
Wrongstuff is offline  
Old 6th Jan 2007, 04:16
  #8 (permalink)  
 
Join Date: Apr 2004
Location: near EDDF
Posts: 775
Likes: 0
Received 0 Likes on 0 Posts
The electric pump starts automatically when one of the engines is started. It then operates continuously until the two engines are stopped.

Blue ELEC PUMP pb-switch
AUTO” ( pb switch in )
● In flight:
- with the BLUE ELEC PUMP pushbutton at AUTO and AC power available, the electric pump operates.
● On Ground:
- the electrical pump is energized, provided one engine is running ,or
- the Blue Pump OVRD pb switch on the 50VU is pushed in.

OFF”( pb switch out )
● OFF illuminates white
● the pump is de-energized
● deactivates the FAULT LT except at overheat-conditions.
IFixPlanes is offline  
Old 6th Jan 2007, 09:20
  #9 (permalink)  
Thread Starter
 
Join Date: Jul 2006
Location: 'tween posts
Posts: 197
Likes: 0
Received 0 Likes on 0 Posts
still trying to figure out why blue pump sw is guarded and not the green or yellow?
gearpins is offline  
Old 6th Jan 2007, 10:20
  #10 (permalink)  
 
Join Date: May 2004
Location: UK
Posts: 715
Likes: 0
Received 0 Likes on 0 Posts
As I see it, the pb is guarded as it would not be desirable in an ops normal situation to turn off the blue system pump for the reasons given by IFixPlanes. I am assuming to turn off the pump is NOT as irreversible action however, so whether or not you would need crew confirmation when operating the pb, as is required with any other guarded sw, is another question!
BitMoreRightRudder is offline  
Old 6th Jan 2007, 14:41
  #11 (permalink)  
 
Join Date: Mar 2005
Location: England
Posts: 730
Likes: 0
Received 0 Likes on 0 Posts
It's guarded because you don't want someone accidentally turning on the blue pump on the ground when someone is working on the aircraft.

As for my first reply being rubbish, I don't need to read the books as I work on them day in day out. I am correct
Fargoo is offline  
Old 6th Jan 2007, 14:57
  #12 (permalink)  

Dog Tired
 
Join Date: Oct 2001
Location: uk
Posts: 1,688
Likes: 0
Received 1 Like on 1 Post
Fargoo, relax. The o'head panel sw is an OFF sw, not an ON one. Nothing will happen if you poke it on the ground.
The maint sw is different; we are not talking about that, however.
You are confusing the switches, I fear.
Now let's all be friends.
fantom is offline  
Old 6th Jan 2007, 15:10
  #13 (permalink)  
 
Join Date: Mar 2005
Location: England
Posts: 730
Likes: 0
Received 0 Likes on 0 Posts
Yep, I see I have gone off on a tangent.
What a plum
I was talking about the blue pump override sw, forgot about t'other one
Fargoo is offline  
Old 6th Jan 2007, 15:12
  #14 (permalink)  

Dog Tired
 
Join Date: Oct 2001
Location: uk
Posts: 1,688
Likes: 0
Received 1 Like on 1 Post
Now, 99% of posters here will not reply like that (me included).
I congratulate you. I mean it.
fantom is offline  
Old 6th Jan 2007, 15:18
  #15 (permalink)  
 
Join Date: Mar 2005
Location: England
Posts: 730
Likes: 0
Received 0 Likes on 0 Posts
I feel a bit of a plonker to be honest but don't agree with going back and editing old posts to make myself look better.
Poor old Gearpins is probably totally confused now
Ta for your reply fantom
Fargoo is offline  
Old 6th Jan 2007, 15:25
  #16 (permalink)  
 
Join Date: Dec 1998
Location: .
Posts: 2,997
Likes: 0
Received 0 Likes on 0 Posts
Cool

I believe that the guard was added by airbus after someone at the pointy end operated it by mistake.

By putting a guard over the switch it then has to be a 'positive' action required to operate the said switch. i.e. are you sure you really want to press this switch?
spannersatcx is offline  
Old 6th Jan 2007, 16:01
  #17 (permalink)  
 
Join Date: Oct 2002
Location: ----
Age: 44
Posts: 1,425
Likes: 0
Received 0 Likes on 0 Posts
Sorry guys to add more confusion..
The overhead Blue override button (on the maintanance panel) is gaurded, ok I get this one and its function:
i.e. when you have to retract the flaps on stand and you will select the yellow and then the blue elec pump on by checking blue elec switch on auto pos on the hyd panel and blue override on the maintanaince panel)..
But the blue elec pump switch on the Hyd panel is not garded, the Rat yeas but that's a different story.
And its position in light off conf (normal pos) is auto with OFF in white light and Fault in Amber.
So in my opinion the 3 pump swithces on the hyd panel are all the same with a different switch on the maintanaice panel, garded but with a different function..
Correct?
Speevy
Speevy is offline  
Old 7th Jan 2007, 18:03
  #18 (permalink)  
 
Join Date: Oct 2002
Location: ----
Age: 44
Posts: 1,425
Likes: 0
Received 0 Likes on 0 Posts
Sorry..
checked today on hyd panel, I was wrong: the blue elec pump it's garded...
Speevy
Speevy is offline  
Old 7th Jan 2007, 23:52
  #19 (permalink)  
Thread Starter
 
Join Date: Jul 2006
Location: 'tween posts
Posts: 197
Likes: 0
Received 0 Likes on 0 Posts
how about 330,340 etc? is it the same? can anyone through some light on it?
gearpins is offline  
Old 8th Jan 2007, 00:46
  #20 (permalink)  
 
Join Date: Jan 2006
Location: Georgia, USA
Posts: 454
Likes: 0
Received 0 Likes on 0 Posts
While I have no experience on the A320, I do know the reason some switches are guarded and some are not. Systems with guarded switches have no back up so it is protected to prevent inadvertent selection.
glhcarl is offline  


Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.