747 Classic cold soaked APU
Thread Starter
Join Date: Sep 2002
Location: up north
Posts: 19
Likes: 0
Received 0 Likes
on
0 Posts
747 Classic cold soaked APU
I heard you can open the APU door inflight on the Classic to get the thing spinning to warm its vital bodily fluid's. Our engineers have been having some trouble firing it up on the ground after a long flight. If so is it written in the BOM. I dont have the good book with me at the moment.
Any help is much appreciated.
Any help is much appreciated.
Join Date: Aug 2005
Location: fairly close to the colonial capitol
Age: 55
Posts: 1,693
Likes: 0
Received 0 Likes
on
0 Posts
I'm no expert on this type..........
I would think the procedure would involve switching APU on then pulling the APU Battery bus - APU Door P83 circuit breaker after a bit which feeds the door motor, then APU switch off. May have to pull other CBs to properly accomplish this. Not sure of how much air you need for that - the Air/Ground relay prevents the door driving full open while airborne.
A FE or old-timer wrenchie ought to know the right answer to this one.
A FE or old-timer wrenchie ought to know the right answer to this one.
Join Date: Jul 2005
Location: Honolulu
Posts: 196
Likes: 0
Received 0 Likes
on
0 Posts
There are some aircraft certified for inflight apu use. They have a different door with a scoop on it. You can see it while the door is closed its pretty obvious. We do have an occasional cold soak problem, but I have not heard of spinning it in flight.
Join Date: Mar 2000
Location: Suitcase....
Posts: 311
Likes: 0
Received 0 Likes
on
0 Posts
IIRC, there is a CB panel in the overhead right by door 5L. There is an APU battery charger CB as well as a APU battery warmer CB. If you pull and reset both of those, that seems to do the trick.
In addition, placing the APU switch to ON will open the door. It seems to work very well below 10.000'.
In addition, placing the APU switch to ON will open the door. It seems to work very well below 10.000'.
The Reverend
Join Date: Oct 1999
Location: Sydney,NSW,Australia
Posts: 2,020
Likes: 0
Received 0 Likes
on
0 Posts
The APU Master switch has three positions; START-ON-STOP. ON- opens APU door,Opens Apu fuel valve,Starts AC or DC fuel pump. Opening APU door in flight by selecting Master Switch to on was a common practice in our operation to facilitate APU start after landing.
Join Date: Dec 1998
Location: .
Posts: 2,995
Likes: 0
Received 0 Likes
on
0 Posts
Door opens to 50% in flt compared to on the ground, which is why you have to be careful going into flt mode when on the ground as the APU can surge/stall when the door goes to 50% open/closed.
I wouldn't recommend pulling cb's in flt, one of them is tied into pressurisation on our a/c!
I wouldn't recommend pulling cb's in flt, one of them is tied into pressurisation on our a/c!
Join Date: Aug 2006
Location: Colorado
Age: 59
Posts: 79
Likes: 0
Received 0 Likes
on
0 Posts
Exactly but two more things. We do it on final appraoch to get the turbine spinning, and only on acft. that have the scoop (Inflight Start certified).
The Reverend
Join Date: Oct 1999
Location: Sydney,NSW,Australia
Posts: 2,020
Likes: 0
Received 0 Likes
on
0 Posts
We do it on final appraoch to get the turbine spinning, and only on acft. that have the scoop (Inflight Start certified).
Join Date: Sep 2006
Location: Far East
Posts: 1
Likes: 0
Received 0 Likes
on
0 Posts
I was always taught that cold soak is a term used during certification trials and if an APU won't start at the end of a sector it has a problem. We weren't allowed to sign based on 'suspect due cold soak'.
Join Date: Feb 2006
Location: Stateside
Posts: 36
Likes: 0
Received 0 Likes
on
0 Posts
Ccold soaked Whale APU
I heard you can open the APU door inflight on the Classic to get the thing spinning to warm its vital bodily fluid's. Our engineers have been having some trouble firing it up on the ground after a long flight. If so is it written in the BOM. I dont have the good book with me at the moment.
Any help is much appreciated.
Any help is much appreciated.
Very common with prior employer to have FE open APU inlet door on final approach so it would spool up when started on taxi in. Was very effective after a crossing with very cold temps at ALT.
Join Date: Mar 2000
Location: Suitcase....
Posts: 311
Likes: 0
Received 0 Likes
on
0 Posts
That was the reason the batter charger CB and the Blanket CB were pulled back by door 5L. The loss of power and re-application of power puts the chager in the high mode, same with the blanket..