ILS DME tuning in the A300
Thread Starter
Joined: Sep 2002
Posts: 312
Likes: 0
From: zz plural 5
ILS DME tuning in the A300
The A300 with (sperry)Honeywell fms will allow manual tuning of vor dme for display on the RMI.How do you display ILS DME?The fms appears to reject any ils entry and selection of the nav switch to ILS does not always guarantee ILS DME display on the PFD.
How do you get around this problem?
How do you get around this problem?

Joined: May 1999
Aviation Qualifications: ATP+Mil
Posts: 27,401
Likes: 857
From: Quite near 'An aerodrome somewhere in England'
During an ILS approach, the ILS/DME is autotuned by the FMS and the ILS/DME distance is displayed in the lower left corner of both PFD. The 'nav switch' on the EFIS secondary control panel must be set to ILS.
Setting the switch to VOR will enable you to tune VOR/DME stations using the VOR frequency controller, but not, as far as I'm aware, ILS/DME frequencies.
Setting the switch to VOR will enable you to tune VOR/DME stations using the VOR frequency controller, but not, as far as I'm aware, ILS/DME frequencies.
Joined: Mar 2006
Posts: 1,974
Likes: 0
From: Choroni, sometimes
During an ILS approach, the ILS/DME is autotuned by the FMS and the ILS/DME distance is displayed in the lower left corner of both PFD. The 'nav switch' on the EFIS secondary control panel must be set to ILS.
Setting the switch to VOR will enable you to tune VOR/DME stations using the VOR frequency controller, but not, as far as I'm aware, ILS/DME frequencies.
Setting the switch to VOR will enable you to tune VOR/DME stations using the VOR frequency controller, but not, as far as I'm aware, ILS/DME frequencies.
- ILS frequ. can be tuned in the VOR ctrl pnl
regards
Thread Starter
Joined: Sep 2002
Posts: 312
Likes: 0
From: zz plural 5
I was very familiar with all of the above,the problem is that the old bus can be very loath to display it on the pfd,and the fms will not allow any manual tuning on the prog page of ils.
I am talking about the A300-600 series with efis and honeywell fms.
I am talking about the A300-600 series with efis and honeywell fms.
Thread Starter
Joined: Sep 2002
Posts: 312
Likes: 0
From: zz plural 5
Hetfield ,so if you are doing a cat3, how do you get the ILs dme up if the bus has decided not to show you on the pfd?With the Smiths fms you could cdu tune it to display it on the rmi,but this is not possible with the honeywell as it only allows vor's on the prog page to be remote tuned.
Also there are a few non-precision approaches that use the ils dme for step down fixes( Manchester springs to mind).Again what do you do if the dme does not display on the pfd.Do you store the dme as a new navaid and will it display it??
Also there are a few non-precision approaches that use the ils dme for step down fixes( Manchester springs to mind).Again what do you do if the dme does not display on the pfd.Do you store the dme as a new navaid and will it display it??
Joined: Mar 2006
Posts: 1,974
Likes: 0
From: Choroni, sometimes
Hetfield ,so if you are doing a cat3, how do you get the ILs dme up if the bus has decided not to show you on the pfd?With the Smiths fms you could cdu tune it to display it on the rmi,but this is not possible with the honeywell as it only allows vor's on the prog page to be remote tuned.
Also there are a few non-precision approaches that use the ils dme for step down fixes( Manchester springs to mind).Again what do you do if the dme does not display on the pfd.Do you store the dme as a new navaid and will it display it??
Also there are a few non-precision approaches that use the ils dme for step down fixes( Manchester springs to mind).Again what do you do if the dme does not display on the pfd.Do you store the dme as a new navaid and will it display it??
- Tune the respective ILS frequency in the VOR ctl pnl
- Read ILS DME on PFD
For Cat 3 you should do that only at start of final descent cause on the respective PFD you have no ILS indication
regards




