Airbus 319 emeregency evacuation
Thread Starter
Joined: Aug 2006
Posts: 7
Likes: 0
From: italy
Airbus 319 emeregency evacuation
Hi gentlemen
I'm reading the Emergency evacuation checklist, and after "Agents discharge" a note says "Engine agent 2 is not available" do you know why ?
maybe because the DC2 is not powered anymore?
thank you
I'm reading the Emergency evacuation checklist, and after "Agents discharge" a note says "Engine agent 2 is not available" do you know why ?
maybe because the DC2 is not powered anymore?
thank you
Joined: Jul 2006
Posts: 204
Likes: 0
From: 'tween posts
At Stations!!
Fly4passion
yes mate you answered it yourself:
-ENG MASTER (ALL) OFF(both GEN goes off
)
Associated LP and HP valves close
-FIRE Pushbuttons (ALL: ENG and APU) PUSH(so does the Apu
-AGENTS (ENG and APU) AS RQRD(both DC bus1&2 drop off)
Engine Agent 2 is not available.
The use of agents is required if the ENG FIRE or APU FIRE is displayed
hint: look up dc bus 1+2 fault list of inop not displayed on ecam
hope that helps