Go Back  PPRuNe Forums > Flight Deck Forums > Tech Log
Reload this Page >

Metro auto ignition

Wikiposts
Search

Notices
Tech Log The very best in practical technical discussion on the web

Metro auto ignition

Thread Tools
 
Search this Thread
 
Old 27th June 2004 | 06:46
  #1 (permalink)  
Thread Starter
 
Joined: Jun 2004
Posts: 11
Likes: 0
From: Australia
Metro auto ignition

In relation to the Metro 3. Is the auto ignition that is activated on pwr loss, activated by a speed signal (less than 70%max rpm), or by a pressure transducer switch when a negative torque set up occurs?
MerlinMetro is offline  
Old 30th June 2004 | 04:05
  #2 (permalink)  
Thread Starter
 
Joined: Jun 2004
Posts: 11
Likes: 0
From: Australia
Question

There must be some metro drivers out there who know the answer???
MerlinMetro is offline  
Old 30th June 2004 | 06:00
  #3 (permalink)  
20 Anniversary
 
Joined: Aug 2002
Posts: 181
Likes: 0
From: no fixed address
My guess...

The metros that I have flown all had the later version of the two ignition systems available, where you had OFF, which you could start in, but have no 'NTSing' feature (not normally used), normal flight was in AUTO ignition mode, and CONTinuous ignition was available for icing or turbulent conditions at pilot discretion - and also comes on when an 'NTSing' condition was present.

The system would not come on when there was only Negative Torque sensed, but there had to be less than FLT IDLE rpm on the prop, so depending how well its rigged, less than 70%.

If anyone else has other ideas, would love to hear them too.

ABC
VH-ABC is offline  
Old 30th June 2004 | 17:44
  #4 (permalink)  
 
Joined: Jun 2001
Posts: 518
Likes: 0
From: Chicago, IL, USA
I knew I'd need this one day

I used to be a Metro III system's instructor (it's been a few years!) but I still have a copy of my Metro Systems book.

<< Selecting the "AUTO" position provides electrical power to the NTS pressure switch through both poles of the ignition selector switch and the relaxed ignition mode relay. The engine mounted NTS pressure switch closes when negative torque (high oil pressure) is sensed, providing power to the ignition exciter. Once the pressure switch has closed, it will remain closed for approximately 30 seconds after the negative torque condition ceases.>>

So RPM has nothing to do with it.

But there is an NTS lock-out when the power levers are brought back for landing. Nobody needs two NTSing propellers when you're trying to flare.

I hope that answered your question.
zerozero is offline  
Old 1st July 2004 | 05:17
  #5 (permalink)  
Thread Starter
 
Joined: Jun 2004
Posts: 11
Likes: 0
From: Australia
Thanks

Thanks that answers it zerozero
MerlinMetro is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2026 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.