Tire Inflation Procedures

Hello All!

I visited today a company that specializes in aircraft tire maintenance - actually they are a customer of mine. They mainatain and inflate aircraft tyres mainly for B-737, A-320, B-757 and RJ.

They currently use Nitrogen in 10m3 cylinder and they want to start using a Nitrogen generator. We discussed the issues of providing sufficient pressure for the 24 hour test etc.. As a side note they are currently passing the evaluation by JAA so I assume they are serious.

My question for those familiar with these kind of procedure what do you use tanks or Nitrogen generator? I am most intreseted if you are working outside the airport but any contribution would be most welcome. Procedure equipment used capacities of cylinders or nitrogen generator....


I like to help them not because they are my customers but because it is my only aviation related customer.


Rwy in Sight
Rwy in Sight is online now  
Old 15th Nov 2003, 06:33
  #2 (permalink)  

Self Loathing Froggy
 
Join Date: Jun 2002
Location: elsewhere
Age: 18
Posts: 546
Likes: 0
Received 0 Likes on 0 Posts
Not a direct answer to your question, but it seems that industrial gas companies are more interested in providing nitrogen generators than cylinders to inflate tires . See for instance :
http://www.airliquide.com/en/busines...eronautics.asp
http://www.airliquide.com/en/medias/...es_filling.pdf
Bre901 is offline  
Old 20th Nov 2003, 15:40
  #3 (permalink)  
 
Join Date: May 2003
Location: Portland, Oregon USA
Posts: 4
Likes: 0
Received 0 Likes on 0 Posts
My experience is using Nitrogen generator in US Coast Guard. You use the generator to fill bottles that you already own. You wouldn't want to provide very high pressure piping thruout the facility. The generator chugs away unattended and charges the bottles, you then put the bottles on the typical trolley and take the Nitrogen where you want it. Our generators would fill a bottle to just shy of 3300 PSI in about 8 hours from empty. We did this in Alaska and shipboard where delivery was a little difficult. The US Navy has a cart with a series of 6 bottles on it that uses the Nitrogen pressure from one bottle to turn a very high pressure pump and boost the pressure from the other bottles up to approximatly 4500 PSI for charging their very high pressure accumulators. The Osprey has 5000 PSI hydraulic systems so they must be able now to obtain at least that for flight control hydraulic system accumulator charging.
MAINTENANCE CONTROL OUT
eskimotail is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.