Post ATR42-300 operational procedure - engine cool time

A note in the "after landing" checklist (normal procedures) of the ATR42-300 states: keep engine running at least one minute at ground idle power (condition lever between MAX and MIN RPM) before shutdown to assist in reducing residual heat build up in the engine and nacelle. Can someone please help to explain the technical significance and impact on the economic life of the engine of keeping the condition lever at the minimum or maximum RPM stops or midway between the two stops i.e. in which exact position would you derive maximum economic benefit for the life of the engine. Thank you.
manene is offline  
Old 22nd Oct 2001, 00:57
  #2 (permalink)  
 
Join Date: Dec 1999
Location: UK
Posts: 52
Likes: 0
Received 0 Likes on 0 Posts
Post

Once the power levers have been brought to ground idle it doesn't matter where the condition levers are between min & max - the ECU schedules enough fuel to keep the props turning at approx 71% (to give you AC Wild power). Normally the condition levers will still be at max from your landing. Of course you can feather one prop while taxiing in, but don't shutdown until the elapsed time has passed - lets the oil/engine temperature even out.

PS Any spare jobs for ATR drivers in Cape Verde?
Waveman is offline  
Old 22nd Oct 2001, 16:07
  #3 (permalink)  
 
Join Date: Oct 2001
Location: Tenerife, sometimes?
Age: 58
Posts: 55
Likes: 0
Received 0 Likes on 0 Posts
Post

The colder the engine is when you suht down it the colder it will be when you start it again, this in return means that you need less time with the starter ON before you get a "cold" temperature to start it without a hot start, remember that the 200 Cº limit is not so good in practice.
Also shuting down colder means that you will get to your times/cycles limits parts in better condition and thus cheaper shop visits.
Mago is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.