Wikiposts
Search
Tech Log The very best in practical technical discussion on the web

fuel tanks

Thread Tools
 
Search this Thread
 
Old 25th Mar 2001, 06:45
  #1 (permalink)  
srl
Guest
 
Posts: n/a
Post fuel tanks

Hi, hope someone out there can help me. I am trying to find out on A330/340, B777, B747-400 how many fuel tanks do they have and where located. from search and manufacturers sites I have only found half the story. I know where tanks are on 747 but not the capacity. I can not find anything on 777. 330/340 I know has stab tank, ?capacity. on 340 mention has been made(from search) inner and outer, ?are outer just right at the tips and inners are main wing tanks. Thank for any help you can give me to fill in the blanks.
 
Old 25th Mar 2001, 07:41
  #2 (permalink)  
HighSpeed
Guest
 
Posts: n/a
Post

srl,

this is for the b777-200IGW, other models might have different capacity.

LEFT 36,200 liters 29,100 kgs
CENTER 98,800 liters 79,300 kgs
RIGHT 36,200 liters 29,100 kgs

* at SG 0.8029

there are also 2 surge tanks, 1 at outboard of each wing tanks where fuel will eventually flow back into the wing tanks.

HS

edited for clarity...

[This message has been edited by HighSpeed (edited 25 March 2001).]
 
Old 25th Mar 2001, 16:58
  #3 (permalink)  
gas path
Guest
 
Posts: n/a
Post

B744

Code:
                  gallons  lbs  litres   kgs

Centre Wing       17164  114999  64973  52162

2+3 main          12546   84058  47492  38128

1+4 main PW/RR     4482   30029  16966  13621

1+4 main GE        4372   29292  16550  13287

2+3 res.           1322    8857   5004   4018

stab               3300   22100  12492  10029

total PW/RR       57164  382999 216389 173725

total GE          56944  381525 215556 173057
Tank layout is: reserve tanks are outboard of the outboard pylons mains 1+4 between the pylons and mains 2+3 between the inboard pylons and the fuselage, centre wing tank as it implies, between the inboard mains. The vent surge tanks are at the wing tips (they will hold 125 galls each). Stab. tank inner two thirds of the stabilizer and one vent surge tank on the r/h side. (that will hold 70 galls I think).

DAMN and BLAST Apologies it looks such a mess.......I give up!

edited for format - Tech Log moderator

[This message has been edited by Checkboard (edited 26 March 2001).]
 

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.