Old 27th Jul 2007, 07:47
  #1 (permalink)  
Thread Starter
 
Join Date: May 2005
Location: Europe trying to enjoy retirement “YES”
Posts: 372
Likes: 0
Received 0 Likes on 0 Posts
AW 139 Technical Question.

Yes I know a thread exists, however I have tried the search to find it again and no luck (old fart and computers I expect) and trawled through the back pages, so a link would help from them what know it. Though the last time I looked little info on above.
Question, Starter for 10 points: Any info on the history of “Hydraulic “failures or indicated failures. Pilot’s perspective and Engineers input welcome.
Bonus points available depending on response.

Many thanks

outhouse
outhouse is offline  
Old 27th Jul 2007, 14:20
  #2 (permalink)  
 
Join Date: Nov 2003
Location: Abu Dhabi
Posts: 1,079
Received 5 Likes on 3 Posts
With the new servo pressure switches the indicated failures are gone...

Not a big issue if you are talking about the "1 SERVO" or "2 SERVO" lights.

Regards.
Aser
Aser is offline  
Old 27th Jul 2007, 16:54
  #3 (permalink)  
 
Join Date: Nov 1998
Location: UK
Posts: 111
Received 0 Likes on 0 Posts
WE have had indications of a No2 filter blockage on the systems page of the MFD. I am told this is caused by the pressure switch in the bypass being triggerd by a momentary increase in pressure as the gear is lowered, no actual blockage apparent. Have changed several pressure switches as a result
pitchlink is offline  
Old 29th Jul 2007, 03:58
  #4 (permalink)  
 
Join Date: Jun 2006
Location: vancouver
Posts: 81
Likes: 0
Received 0 Likes on 0 Posts
Same issue with our ship, changing the by pass switch did nothing, and it even if you keep the gear down it will by pass anyway. Check the filter periodically to be safe. Flush your hydraulic reservior every 24 months. As far as I know Agusta has no fix yet for this poblem.
AB139engineer is offline  
Old 29th Jul 2007, 04:37
  #5 (permalink)  
 
Join Date: Oct 2005
Location: Button Moon
Posts: 36
Likes: 0
Received 0 Likes on 0 Posts
Same as above regarding bypass and servo indications. However have still been troubled with servo CAS messages after heavy rain, high humidity even with the new servo switches.

We have had a total loss of pressure on the number 1 system if my memory serves me correct. Pump made lots of scary noises from what I gather. System was isolated before pump had chance to overheat and scary noises stopped as there was still enough fluid trapped in that part of the system. Did not overheat after system had been isolated. Aircraft landed safely with no problems on the No2 system.

In addition to this we have had one instance of the No4 pump losing pressure early on shutdown. During further investigation it was found that it was actually the No 2 pump that was losing pressure early as the No 4 sensor was actually routed to the No 2 pump and vice versa. This routing was found to be the same on all of our aircraft. Maybe thats an Italian thing???

Hope this helps.

Last edited by platinumpure; 30th Jul 2007 at 05:14.
platinumpure is offline  
Old 30th Jul 2007, 06:40
  #6 (permalink)  
 
Join Date: Sep 2004
Location: daworld
Posts: 642
Likes: 0
Received 2 Likes on 2 Posts
We've had the Hyd Pressure filter popping on one machine, but managed to fix it after changing the Hyd PCM (warranty )
We got sick of changing pressure filters for no reason. I emailed Agusta and they confirmed it is a known problem, and is like that because of (according to them) two main issues.
One is that the hyd press filter is too fine. They are going to a coarser filter. It isn't because of contamination (usually!!) but because of pressure pulses. These pulses are 'stopped' by the filter, creating enough press diff to set off the press diff switch, which is the other problem. The press diff switch reacts too quickly, and picks up a nano seconds worth of press diff out of limits.
Agusta assure me (!!!) that they are working on new filters and press diff switches.
Apart from that, we haven't had any other hyd issues (touch wood )
Agusta also informed us that they don't believe it necessary to pull the press filter to check for contamination, unless the return filter is also popped. Just reset the popout. If your company requires it in writing, send an email to tech support person you use, and refer them to the guy we use at Agusta. If you need his name, PM me.
Cheers

Last edited by noooby; 30th Jul 2007 at 06:42. Reason: ooosless spelling
noooby is offline  
Old 30th Jul 2007, 16:06
  #7 (permalink)  
Thread Starter
 
Join Date: May 2005
Location: Europe trying to enjoy retirement “YES”
Posts: 372
Likes: 0
Received 0 Likes on 0 Posts
Hi,
To all that responded to my enquiry very many thanks. It’s been very informative and I am sure will be a great help. Should I experience any different problems in the future I will share my experiences with you all.
Regards

Outhouse.
outhouse is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.