Hazards of Gas Turbine Exhaust Plumes
Thread Starter
Joined: Oct 2003
Posts: 1,300
Likes: 0
From: Canberra Australia
Hazards of Gas Turbine Exhaust Plumes
Would you have any hesitations in flying a lighty or a chopper through the exhaust plumes of gas turbine powered electricity power generator/s.? If so, how close is too close?
Many units are mounted vertically and all seem to have vertical exhaust stacks.
Hazards may be extreme at close quarters from high velocity high temperature gases at depleted oxygen levels and much turbulence.
Do any sites have warnings and no-go areas.
I expect that some navy chopper pilots have learned the hard way in close association with gas turbine powered ships.
Perhaps no-one has yet considered flight testing.
Many units are mounted vertically and all seem to have vertical exhaust stacks.
Hazards may be extreme at close quarters from high velocity high temperature gases at depleted oxygen levels and much turbulence.
Do any sites have warnings and no-go areas.
I expect that some navy chopper pilots have learned the hard way in close association with gas turbine powered ships.
Perhaps no-one has yet considered flight testing.
Joined: Dec 2001
Posts: 1,835
Likes: 3
From: Philadelphia PA
Great point.
Plumes of any sort can hide hazards. I'm reminded of the piston engine guys who found that humidity was a lot higher a long way downwind of the steam plumes from electrical power generating stations.
Air temperature being higher is also an issue - affects performance quite a lot, especially turbine engine performance.
Plumes of any sort can hide hazards. I'm reminded of the piston engine guys who found that humidity was a lot higher a long way downwind of the steam plumes from electrical power generating stations.
Air temperature being higher is also an issue - affects performance quite a lot, especially turbine engine performance.

Joined: Dec 2004
Aviation Qualifications: ATP+Mil
Posts: 95
Likes: 8
From: Berwick-upon-Tweed
Doesn't help for onshore, I'm afraid, but there is good guidance for offshore operations in UK CAA CAP 437
CAP 437: Offshore Helicopter Landing Areas - Guidance on Standards | Publications | CAA
CAA Paper 2007-02 The visualisation of offshore gas turbine plumes is also worth a look
CAA Paper 2007/02: Visualisation of Offshore Gas Turbine Gas Plumes | Publications | CAA
CAP 437: Offshore Helicopter Landing Areas - Guidance on Standards | Publications | CAA
CAA Paper 2007-02 The visualisation of offshore gas turbine plumes is also worth a look
CAA Paper 2007/02: Visualisation of Offshore Gas Turbine Gas Plumes | Publications | CAA
Joined: Sep 2004
Posts: 187
Likes: 0
From: Berkshire, UK
The CAA stuff is probably a good bet. In 1987, on behalf of the CAA, an independent research company studied "Helideck wind flow distortion and hot gas plume dispersal in relation to helicopter operational difficulties when operating to offshore oil/gas production facilities."
We didn't do actual flight testing, but did computer modelling and pilot experience studies, plus simulator examination of pilot reaction to taking off from and landing on offshore decks, with simulated turbulence from structures and gas plumes.
One of the documents we had hold of was a study undertaken by BP on the effects on gas turbine engines of flying through plumes. BP may still have a copy of that in their archives.
We didn't do actual flight testing, but did computer modelling and pilot experience studies, plus simulator examination of pilot reaction to taking off from and landing on offshore decks, with simulated turbulence from structures and gas plumes.
One of the documents we had hold of was a study undertaken by BP on the effects on gas turbine engines of flying through plumes. BP may still have a copy of that in their archives.
Cleverly disguised as a responsible adult
Joined: May 2007
Posts: 1,117
Likes: 0
From: On the western edge of The Moor
If talking about land based sites, most, if not all, of these have a heat recovery system within the exhaust gas stream to heat water and power a steam turbine.
Combined cycle - Wikipedia, the free encyclopedia
this being the case the heat recovery will lower the final output exhaust plume to a fairly low figure.
Combined cycle - Wikipedia, the free encyclopedia
this being the case the heat recovery will lower the final output exhaust plume to a fairly low figure.
Joined: Oct 1999
Posts: 628
Likes: 0
From: Ireland
You may find this interesting:
Air Accident Investigation UnitFull List of Reports
A Jetranger flew into the exhaust plume of Ringsend power station in Dublin and came down on the beach.
Air Accident Investigation UnitFull List of Reports
A Jetranger flew into the exhaust plume of Ringsend power station in Dublin and came down on the beach.
Joined: Jun 2003
Posts: 288
Likes: 0
From: USA
There have been many incidents of engine power loss associated with oxygen depleted air. These have involved exhaust plumes from gas turbine and coal powered plants. There have also been engine power loss incidents associated with volcanos.
Joined: Dec 2005
Posts: 74
Likes: 0
From: Wiltshire
Very real hazard on offshore platforms. I am not very experienced on rigs but one day went through the exhaust of one in Morecombe Bay, the loss of lift was quite noticeable. Unsure whether you need to focus your research on the effect on engine power or the local rapid increase in density altitude due to heating and subsequent loss of rotor performance. My money is on the latter.
Joined: Mar 2009
Posts: 10
Likes: 0
From: Somewhere Nice
I have run across a stream of oxygen depleted air and loss of power is quite noticeable. I fly high performance helicopters and this is something to really look for, specially in confined areas near coal mines or any other area where oxygen might be at a minimun.
Hippopotomonstrosesquipidelian title
Joined: Oct 2006
Posts: 1,825
Likes: 1
From: is everything
confined areas near coal mines

Joined: Feb 2005
Posts: 4,581
Likes: 0
From: flyover country USA
I suspect that the power loss in such an exhaust plume is more due to the elevated air temperature than oxygen depletion. I say this because, in every engine control system I'm familiar with, the control will adjust fuel flow to maintain RPM (or some other selected parameter like turbine temperature) regardless of fluctuation in O2 content.
Your OAT gage in the cockpit may not respond fast enough to give you a true picture of temperature changes.
Your OAT gage in the cockpit may not respond fast enough to give you a true picture of temperature changes.
Joined: Mar 2006
Posts: 1,771
Likes: 0
From: West Sussex
Possibly of interest,
Alex Henshaw used to navigate Spitfires he was testing back home using the power station cooling towers ( and their plume ) as a guide to Castle Bromwich - he remarked he was a little concerned that as he let down over a chimney, one day he might end up inside it !
Alex Henshaw used to navigate Spitfires he was testing back home using the power station cooling towers ( and their plume ) as a guide to Castle Bromwich - he remarked he was a little concerned that as he let down over a chimney, one day he might end up inside it !
Joined: Jan 2008
Posts: 123
Likes: 0
From: East in the hills
I think Corsairs posted link to the AAIU report of an identical incident to the question posed is excelent reading
It is not just the heat and condensation but the fact that the stream is less than a 1/3 of the recommended safe oxygen content for turbine (or for that matter piston) operation. Note though the AC was very close and in a low forward speed.
Perhaps all exhaust flues should be painted red and white as is the norm in the Eastern block countries
There is a nice new gas turbine plant with very high flue stack right alongside the East side of the A74m 1 mile north of Lockerbie Dumfries. I point this out as it is a popular transit route for low level rotarys following the A74m North to South on VFR running from Carlisle to Scotland, however at cruise speed and at a FL of 1000ft or greater I doubt that the contact time with the depleted air would ever be enough to cause a flameout.
It is not just the heat and condensation but the fact that the stream is less than a 1/3 of the recommended safe oxygen content for turbine (or for that matter piston) operation. Note though the AC was very close and in a low forward speed.
Perhaps all exhaust flues should be painted red and white as is the norm in the Eastern block countries
There is a nice new gas turbine plant with very high flue stack right alongside the East side of the A74m 1 mile north of Lockerbie Dumfries. I point this out as it is a popular transit route for low level rotarys following the A74m North to South on VFR running from Carlisle to Scotland, however at cruise speed and at a FL of 1000ft or greater I doubt that the contact time with the depleted air would ever be enough to cause a flameout.
Last edited by staplefordheli; 20th March 2009 at 14:47. Reason: forgot some text
Joined: Mar 2006
Posts: 1,771
Likes: 0
From: West Sussex
Seeing as plumes by their nature generally show themselves above cloud, isn't painting the towers red & white a bit late ?!
This is supposedly the 21st Century, so how about beacons or marked GPS charts...
This is supposedly the 21st Century, so how about beacons or marked GPS charts...
Thread Starter
Joined: Oct 2003
Posts: 1,300
Likes: 0
From: Canberra Australia
Beside the freeway from Melbourne to Avalon down under is a twin stack gas turbine power station running on diesel. There is no visual evidence of the exhaust plumes. A recent addition to the exhaust stacks are 4 flashing beacons around the tops of each stack.
Does anyone know whether the beacons are a regulatory requirement and is there a NOTAM specifying overflight restrictions?
Does anyone know whether the beacons are a regulatory requirement and is there a NOTAM specifying overflight restrictions?
Joined: Jul 2007
Posts: 80
Likes: 0
From: Belfast
If talking about land based sites, most, if not all, of these have a heat recovery system within the exhaust gas stream to heat water and power a steam turbine.
Combined cycle - Wikipedia, the free encyclopedia
this being the case the heat recovery will lower the final output exhaust plume to a fairly low figure.
Not strictly true. Granted, most of the GT power plants built nowadays are "Combined Cycle" (where the exhaust heats water to power a steam Turbine), however there are still a fair few "Open Cycle" plants around. I work at one such plant, and the GT exhaust exits the top of the chimney at around 500 degrees celsius...
Combined cycle - Wikipedia, the free encyclopedia
this being the case the heat recovery will lower the final output exhaust plume to a fairly low figure.
Not strictly true. Granted, most of the GT power plants built nowadays are "Combined Cycle" (where the exhaust heats water to power a steam Turbine), however there are still a fair few "Open Cycle" plants around. I work at one such plant, and the GT exhaust exits the top of the chimney at around 500 degrees celsius...