PPRuNe Forums

PPRuNe Forums (https://www.pprune.org/)
-   Engineers & Technicians (https://www.pprune.org/engineers-technicians-22/)
-   -   JAR 66 Questions (https://www.pprune.org/engineers-technicians/17804-jar-66-questions.html)

Golden Rivet 11th February 2001 23:06

JAR 66 Questions
 
A question of heat shrink tubing - Exciting I know !

When using heat shrink tubing the heat gun is set

1. Slightly below heat shrink value for tube
2. At heat shrink Value
3. Above the shrink value

Any ideas ?



------------------
Fools rush in where Angels fear to tread

DoctorA300 12th February 2001 11:11

Hi,
The answer is at heatshrink value, but I canīt give you the reference right now.
Brgds
Doc

torquetome 12th February 2001 18:47

I had this question for module 7, the good old airbus (A300/310) MM's say the temp should be set above (100C) the heat shrink temp. Hope this helps

Golden Rivet 12th February 2001 22:30

Thanks chaps

The Weasel 15th February 2001 05:13

How's this for blind guess theory:
Set below and you'll never shrink it.
Set at shrink value and you'll be there all day if the heat gets absorbed by the conductor or blown away when someone leaves the hangar doors open.
Set above and it's got to shrink.
Good luck with the exam.