PPRuNe Forums

PPRuNe Forums (https://www.pprune.org/)
-   Engineers & Technicians (https://www.pprune.org/engineers-technicians-22/)
-   -   DME X &Y channel (https://www.pprune.org/engineers-technicians/313083-dme-x-y-channel.html)

nemohot 12th Feb 2008 04:26

DME X &Y channel
 
hi,
Do any one know when the X channel used and when the Y channel should used of the DME, is there any restriction on the use of X & Y channel? and is the DME frequncy is tide to the ILS frequncy ?

Fargoo 12th Feb 2008 07:12

Hi,
DME is paired to VOR frequencies.
DME uses pulse pairs - X and Y and always uses both as far as i'm aware.
X pulse is spaced at 12 microseconds and Y pulse at 36 microseconds.
Hope this helps :ok:

nemohot 12th Feb 2008 09:51

thanx
 
thanx bro, but i was wondering if that will make different if i choose X channel or Y channel , is the selecting of the X or Y channel depend on some specification or it's back to me to choose what ever i want?

shedhead 14th Feb 2008 01:53

x channels are paired to vor frequencies such as 108.00,108.10, 108.20 etc, y channels to frequencies that go up from 108.05,108.15 and so on so channel selection is not really a manual option but is dependant on the vor frequency selected.