Old 16th Jun 2002, 15:49
  #1 (permalink)  
Thread Starter
 
Join Date: Nov 2000
Posts: 183
Likes: 0
Received 1 Like on 1 Post
oxy explosion at LPL

Two engineers were injured one seriously charging an oxygen cylinder which exploded at Liverpool. The question is should we still be charging O2 in uncontrolled enviroments in this day and age. This practice seems to have been outlawed in many countries. Any thoughts?
Rob_L is offline  
Old 16th Jun 2002, 18:30
  #2 (permalink)  
 
Join Date: Aug 2001
Location: middle east
Posts: 31
Likes: 0
Received 0 Likes on 0 Posts
In My outfit which is of a moderne fleet,we change O2 bottles and charge them in the shop as the a/c are not equiped to charge them in situ.
Excuse my ignorance but i thought it was illegal practice to charge bottles nowadays other than an approved method/workshop.
Sorry to hear of the injuries.
Bullishit is offline  
Old 16th Jun 2002, 21:29
  #3 (permalink)  
 
Join Date: May 2002
Location: somewhere near an airport
Posts: 173
Likes: 0
Received 0 Likes on 0 Posts
well if your working n reg ac then charging onboard is a definate no no ...can/t say now that i am working for an eu company that i have ever seen the rules/instructions for charging oxy onboard

hope the guys are ok but you know who is going to get the blame
nitro rig driver is offline  
Old 16th Jun 2002, 21:44
  #4 (permalink)  
 
Join Date: Sep 2000
Location: UK
Posts: 59
Likes: 0
Received 0 Likes on 0 Posts
Hope the two engineers are OK.Which bottles were being recharged,the crew or the cabin portable type?
rightstuff is offline  
Old 16th Jun 2002, 22:59
  #5 (permalink)  
 
Join Date: Nov 2000
Location: UK
Posts: 16
Likes: 0
Received 0 Likes on 0 Posts
My thoughts are with the injured guys. Here at Big Airways we charge O2 bottles in situ on the aircraft although there are very stringent rules about the process. In days gone by our instrument guys did it because it was thought they were less likely to introduce grease into the process - but now - almost anyone can do it and I'm sure it is only a matter of time before we have an incident. When it happens I quess one of the stringent rules will have been broken and I know who will be considered to be at fault and it won't be the company.
As an aside - what problems are encountered transporting charged cylinders? Does this present an equal risk?
time-ex is offline  
Old 17th Jun 2002, 21:15
  #6 (permalink)  
Thread Starter
 
Join Date: Nov 2000
Posts: 183
Likes: 0
Received 1 Like on 1 Post
Last I heard it was a portable. When it went off the flash was seen from the fire station 300 metres away.

One engineer is reported as badly hurt requiring skin grafts and with eye damage.
Rob_L is offline  
Old 21st Jun 2002, 11:41
  #7 (permalink)  
 
Join Date: Jan 2000
Location: england
Posts: 68
Likes: 0
Received 0 Likes on 0 Posts
Rob_L; was this incident at your company or another?
morroccomole is offline  
Old 25th Jun 2002, 04:47
  #8 (permalink)  
Thread Starter
 
Join Date: Nov 2000
Posts: 183
Likes: 0
Received 1 Like on 1 Post
Channel Express and Emerald
Rob_L is offline  
Old 2nd Jul 2002, 14:55
  #9 (permalink)  
 
Join Date: Oct 1999
Location: Sydney, Australia.
Posts: 13
Likes: 0
Received 0 Likes on 0 Posts
Standard practice for us is to remove bottle place into reinforced container, which is part of the oxy recharge rig and top up bottle. Saves any mishaps. All tools required are in special tool box on the rig as well.
Airbornespanner is offline  
Old 3rd Jul 2002, 21:30
  #10 (permalink)  
 
Join Date: Mar 2002
Location: Reigate, Surrey.
Posts: 9
Likes: 0
Received 0 Likes on 0 Posts
Question Enquiry ???

From an (untrained) observers point of view, can I ask how these elements interact so violently ??? any knowledge is good.
NightHawkZero is offline  
Old 5th Jul 2002, 14:35
  #11 (permalink)  

Self Loathing Froggy
 
Join Date: Jun 2002
Location: elsewhere
Age: 18
Posts: 546
Likes: 0
Received 0 Likes on 0 Posts
Risks of oxygen

Pure oxygen under pressure is so reactive that it will react violently with many solid materials (including cylinder wall), provided an adequate source of ignition energy is given.

That energy maybe as small as a shock, a spark from a steel wrench, or the oxidation of tiny amounts of grease (including fingerprints on exposed parts).

Oxygen filling procedures are stringent and should be followed very carefully. Care and cleanness (sp?) are essential.
Bre901 is offline  
Old 5th Jul 2002, 21:29
  #12 (permalink)  
 
Join Date: Jun 2002
Location: England
Posts: 2
Likes: 0
Received 0 Likes on 0 Posts
Firstly how are the guys doing that were injured?
Bre901 is correct, pure oxygen will react with most things that have a flash point. Even metals at high pressure or temperatures. The more available Oxygen the lower the flash point becomes. Once low enough, any source of ignition will start a fire, more oxygen the faster the fire will burn. That is why cotton clothing should be worn, Synthetics easily produce static sparks.
The fire storms in USA are a typical example. If you think Bread burns in Toaster, dip it in Liquid Oxygen, light it and it will burn like an Signal flare!
Most oxygen systems are made free of anything combustable. (within limits)Clynders are best made from Stainless steel or polished mild steel. Dry Oxygen is used to prevent any rust forming; FeO2 to FeO3, which becomes pourus and can flake off. If a high pressure clynder became pourus the passing Oxygen can accelerate the reaction (which also produces some heat). It also severely diminishes the structual rigidity of the clynder. Thats why they have a shelf life and should be discarded if completely depressurised. If conditions are right the bottle can explode due to the structual faliure, sparks from flying metal can start a fire/ explosion and can destroy an Aircraft. Hence NO PASSENGERS on board whilst charging.
Slow charging is used to minimise leaks, but also reduces vibration, structual stresses, prevents any icing or heat build up within the pipe work and doesn't freeze or melt open the valves.
Hope this explains the procedures we follow when charging Oxygen.
FlukeFixer is offline  
Old 13th Jul 2002, 13:40
  #13 (permalink)  
 
Join Date: May 2001
Location: UK
Posts: 92
Likes: 0
Received 0 Likes on 0 Posts
I've been charging oxygen systems using both Gaseous and Liquid oxygen for about 19 years now, to be perfectly honest this is the first time i've heard of a serious incident whilst charging. I'm not saying that there haven't been any during that time , it's just that I haven't heard of or noticed them. I am intrigued to know what caused this unfortunate accident. Several possible causes instantly spring to mind; Grease on the fittings or tools being used, Failure of a component in the system alowing gas to escape, a spark caused by static or metals rubbing/banging together, dare i say it... Over pressurisation causing a failure ? I hope the Guys make a full recovery and also we gett to know the outcome of any investigation to try to prevent it happening again.

In a similar Vein;
I often cringe when i see fuel being drained or decanted from an aircraft fuel tank or container. Two incidents that spring to mind are:

1) Fuel being drained from an RAF Pembroke at RAF Wildenrath in the 80's, I believe that there was no bonding lead being used and a spark ignited the fuel vapour severely damaging or destroying the A/C and the building.

2) at KAAB Dhahran Saudi Arabia 1999. An F-15 was being drained of the last few gallons of fuel in the brand new ( but Un-ciommisioned) Fuel Shop Hangar. The guy doing the job forgot to attach the bonding lead, he remembered part way through the operation. As he tried to attach the Bonding lead to the A/C a spark jumped and 'Flashed' the fuel vapour, as the Technician (a Saudi Military guy) jumped out of the way he fell & knocked over the draining bucket containing fuel. You can imagine what happened next..... The resultant fire completely destroyed the brand new f-15 A/C and the building !!! as well as badly injuring the technician. I know this to be true as I was actually watching the firemen battling to put out the blaze.

It is also alledged that the Brand new Purpose built Fuel shop/Hangar had a state of the art fire detetection and suppressant sytem installed, however they had been having so many bugs and false alarms it had been turned off !!!

It's often a dangerous world we all work in - be carefull and lucky now.
KwikPhix is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.