Can anyone tell me is it necessary to carry out paralleling check after the D.C.U.'s have been swapped or replaced.
cjg412 is offline  
Old 7th Oct 2012, 03:26
  #2 (permalink)  
 
Join Date: Jun 2009
Location: South East Asia
Posts: 430
Likes: 0
Received 0 Likes on 0 Posts
Bell 212

D.C.U.'s, what are these? ALWAYS post helicopter-related matters in the 'Rotorheads' section where you'll more authoritative replies.
Saint Jack is offline  
Old 7th Oct 2012, 10:19
  #3 (permalink)  
 
Join Date: Oct 2006
Location: USA
Posts: 759
Received 28 Likes on 23 Posts
cjg...

Technically....you should actually perform an operational check of each separate affected DC system prior to any paralleling checks after replacing a DCU...

The M&O was never really clear on this...and if memory is correct it was actually dealt with in Vendor's manuals on DCU.

But straight up... yes...you need to parallel the DCU's if changed out...even if swapped...as the #1 and #2 systems are independent of each other....

w1
wrench1 is online now  
Old 7th Oct 2012, 19:47
  #4 (permalink)  
 
Join Date: Mar 2004
Location: Indonesia
Posts: 289
Likes: 0
Received 0 Likes on 0 Posts
The answer is yes do it. Its easy but holding the screwdriver on the tiny adjustment screw with a slottted head is a skill. Refer to BHT212 MM 96-39. The DC electrics in general are from 96-24 on. Worth a read. PB

Last edited by piggybank; 7th Oct 2012 at 19:47.
piggybank is offline  
Old 8th Oct 2012, 06:31
  #5 (permalink)  
 
Join Date: Jun 2012
Location: Canada
Posts: 21
Likes: 0
Received 0 Likes on 0 Posts
Yeah make sure the plastic insulating sleeve is in place around the test connections where you plug in your multimeter, if the positive probe of your meter shorts out to the case of the DCU it'll fry. This is especially hard on single bus machines since the extra relays are in the way of the number one DCU's probe ports. Don't forget the different voltage setting for cold weather operations.
cbox chip is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.