the difference between underspeed and under frequency ?

they seem to be the same :S i mean isnt frequency directly related to the speed of the CSD ?
so if underspeed occurs under frequency would occure as a consequence for it .
so why there is '' underspeed '' protection ?
makes no sense
flame_bringer is offline  
Old 28th Sep 2009, 15:17
  #2 (permalink)  
 
Join Date: Dec 1998
Location: .
Posts: 2,995
Likes: 0
Received 0 Likes on 0 Posts
Cool

The axial gear differential/hydraulic speed control section in the IDG converts a varying engine input speed of 4,650 - 9,200 rpm, to a constant output speed of 12,000 ±150 rpm. The constant output speed allows the generator section of the IDG to produce ac power with a frequency of 400 ±5 Hz.
spannersatcx is offline  
Old 29th Sep 2009, 10:38
  #3 (permalink)  
 
Join Date: Oct 1999
Location: Adelaide
Posts: 668
Likes: 0
Received 0 Likes on 0 Posts
Is there an underspeed protection or is the underspeed trip the protection ? Think about it.
SeldomFixit is offline  
Old 18th Oct 2009, 07:01
  #4 (permalink)  
Thread Starter
 
Join Date: Sep 2009
Location: bahrain
Age: 35
Posts: 353
Likes: 0
Received 0 Likes on 0 Posts
after researching and asking people i think i understood it now, so correct me if im wrong.
underspeed means if we're shutting off the engine the frequency of the generator frequency goes down and that would trip all the bus tie breakers in a parrallel system due to under frequency protection activation so a speed switch is situated in the CSD to monitor the oil pressure if it goes low due to underspeed ( engine shut off ) it transmits a signal to GCU which trips the generator line contactor of that particular generator only without tripping all the bus tue contactors and all the other generators .
please someone correct me if im wrong.
flame_bringer is offline  
Old 19th Oct 2009, 06:24
  #5 (permalink)  
 
Join Date: Oct 1999
Location: Adelaide
Posts: 668
Likes: 0
Received 0 Likes on 0 Posts
Plus or Minus 5 (Volts/Hz) is the definition of Quality Power - along with correct phase rotation.
SeldomFixit is offline  
Old 20th Oct 2009, 17:44
  #6 (permalink)  
Thread Starter
 
Join Date: Sep 2009
Location: bahrain
Age: 35
Posts: 353
Likes: 0
Received 0 Likes on 0 Posts
yea im talking about the aircrafts that run the generators in parralel eg boeing 727 .
flame_bringer is offline  
Old 23rd Oct 2009, 04:34
  #7 (permalink)  
 
Join Date: Sep 2007
Location: Up left - Down right
Posts: 946
Likes: 0
Received 0 Likes on 0 Posts
An underspeed trip is due to mechanical failure if the CSD or input shaft (or normal engine SD) the result is to only open the GCB. The UF trip will, in a parallel bus system, first trip the Bus tie breaker then GB and Field Relay.
During normal engine SD the Underspeed trips prevents unnecessary loss of bus power and prevents storing nuisance faults.
Short_Circuit is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.