Question a/c cargo compartments - questions

With respect to commonly used medium and long-haul passenger aircraft (any type you are comfortable talking about):

Can someone outline how heating and cooling of lower deck cargo compartments is accomplished? Is there a direct air exchange (air vents removing air from and/or supplying air to the compartment) or is heated/cooled cabin air just passed along the outside of the cargo compartment walls to facilitate a temperature change?

How do cargo compartment temperatures compare to cabin temperatures?

Is there a technical difference with regards to heating/cooling between class C and class D compartments?

How does one verify by looking into a cargo compartment whether this is a class C or a class D compartment?

Last edited by cattlerepairman; 27th August 2004 at 13:00.
cattlerepairman is offline  
Old 28th August 2004 | 22:27
  #2 (permalink)  
 
Joined: Feb 2001
Posts: 25
Likes: 0
From: Left Field
For the last part of your question you might start here.
Cargo Compartment Classification

Regards,
TT
TeamTerminal is offline  
Old 9th September 2004 | 14:34
  #3 (permalink)  
25 Anniversary
 
Joined: Jul 1999
Posts: 134
Likes: 0
From: Big Sky Country
Heating of cargo compartments will depend on the aircraft. 737 classics, the rear hold wasn't heated wihile the forward hold was heated via exhaust air from the equipment cooling vent, this is a fairly common philosophy in the Boeing fleet, the larger aircraft also have temp controlled aft cargos and bulk cargo. This can be controlled from the flight deck for temp sensitive cargos. hope this helps. Don't know how Airbi are heated....
LME (GOD) is offline  
Old 17th September 2004 | 13:04
  #4 (permalink)  
Thread Starter
20 Anniversary
 
Joined: Aug 2004
Posts: 12
Likes: 0
From: Canada
Class D

I read through the classification of cargo compartments.

It appears that both a class C and a class E compartment can be ventilated.
There is no mention of a class D compartment? Yet, I have seen it mentioned frequently.

Is a class D compartment the one where a fire would be starved of oxygen because the compartment is airtight in flight?
cattlerepairman is offline  
Old 20th September 2004 | 17:40
  #5 (permalink)  
25 Anniversary
 
Joined: Mar 2000
Posts: 62
Likes: 0
From: Edinburgh, UK
I thought all class D compartments had to be reclassified as C or E, perhaps that is why.
avoman is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2026 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.