Hi Bkdoss
What would be the protection that would kick in at this point to keep us in the safe envelope?
FCOM, DSC-27-30-10: Alpha/Speed Lock,
If, in the scenario you describe, AOA was above 8.5 degs then the slats would not retract.
If AOA was less than 8.5, then the slats would retract and SRS would attempt to follow 160 kts (or max VLS+25). Depending on Alpha you may get TOGA LOCK with Alpha PROT / up to Alpha Max.
If you insist on blindly following "Go Around flaps" call /procedure then use managed speeds.