If the Yellow Electric Pump is running, following an engine failure, the Status page is missing the blue line 'Apply landing distance procedure'. The machine is also showing the landing capability as CAT 3 B.
The reason for this is that if the Y ELEC PUMP is running, all three hydraulic systems are working, hence you do NOT lose a pair of spoilers... Also you do not lose your CAT 3 B Capability... In our simulator the Y ELEC PUMP shuts down, after there is an electric power transfer (i.e. if the APU starts running and the APU GEN is powered...)