Originally Posted by Sir Korsky
Thanks for making me get the books out 212, I needed a brush up. I was told all models have Blowaway, luckily never flown an A so the jury's out on that one. You get 10 seconds transient at 230 trans torque. DECU limits blowaway power to 115 tq per side.
No juries required! Blowaway requires a FADEC so discount an Allison, an Ariel 1 variant and probably the B model too.

Last edited by 212man; 27th May 2017 at 17:45.