My old, possibly outdated, copy of the 744 AMM in Ch. 71 Ground Running states the following fuel is required to cover the heat exchangers.
Tanks 1/4 - 953 kg
Tanks 2/3 - 2450 kg
This is the mininum amount required in tanks after completing the ground run, not the starting amount.