So APU door swx says >13deg - door open signal to APUC to get starter going, actuator then fails, so although the door signal is open from the door swx, the actuator fails to reach full stroke, as it has failed, therefore after 60secs, although the door is 'open' the actuator is not fully open - EICAS - APU DOOR - ? Then get the MEL out!