I don't know for sure about the Rolls Trent, but on the GEnx, the EICAS engine surge indication means that a continuous or multiple stall condition exists (three or more surge/stall events within 30 seconds) - it would not be displayed for a single surge/recovery.
I'd be mildly surprised if the Trent 1000 logic is meaningfully different.