PPRuNe Forums - View Single Post - V2500 Engine Spool Up Time
View Single Post
Old 11th Dec 2015, 13:54
  #7 (permalink)  
lomapaseo
 
Join Date: Mar 2002
Location: Florida
Posts: 4,569
Likes: 0
Received 1 Like on 1 Post
The motoring for shaft problems is 30 seconds, irrespective of any other parameters. Additionally, if the EGT after the 30 seconds cranking period remains above 250°C (not 100°C), FADEC will schedule additional motoring until residual EGT drops below limit before introducing ignition and fuel.

Is this only with weight on wheels?
lomapaseo is offline