Ground Warning If one of the 3 ADIRU's looses 115 VAC power (the ON BAT light on the ADIRS illuminates illuminates), the 'HORN MECH CALL' sounds with a time delay of 15 seconds, if the A/C is on GROUND. Parallel to this the ADIRU & AVIONICS VENT light in the nose well illuminates.