vilas
FCOM DSC-28-40 Electrical supply, Intertank XFR Valves L2 & R2 are normally supplied by DC2, L1 & R1 supplied by DC ESS SHED bus.
The DC ESS SHED bus is only shed when you are in Emergency ELEC config & the RAT has dropped off line, leaving the buses only powered by the batteries.