Uplinker
The parameters are not changed and although wing leak is triggered above 124degrees the after landing procedure remains same i.e. above 30 degrees for keeping flap1 is not changed. Since it is triggered from slat, after shut down it is possible to retract the flap with yellow electrics though strictly speaking it is not SOP.