CTR tank feeding
Hello Mr. Aikon
CTR tank feeding during T/O is inhibited because our centre tank is equipped with two pumps and because of which only one pump supplies the fuel to its respective engine. In case of failure there is no backup for fuel feeding to that engine. And we are very well aware that T/O is a critical phase.