PPRuNe Forums - View Single Post - 737 Hyd pumps ops
Thread
:
737 Hyd pumps ops
View Single Post
14th February 2015 | 21:55
#
4
(
permalink
)
LEVEL600
Joined:
Mar 2009
Posts:
60
Likes:
0
From:
Prague
EMDP are switched on before engine start usually during cockpit prepartion checklist and switched off after shutdown. EDP sw. are in on all the time, in off position is supplied pump depres. solenoid, which can be overheated/damaged without cooling.
Reply
0
0
LEVEL600
View Public Profile
Find More Posts by LEVEL600