Boeing Normal Mode with split columns
The mechanical link between the two columns will pop out of its detent allowing relative motion if the force carried by that link exceeds 50 lbs.
The average of the left and right column positions is used as the consolidated input to the Normal Mode control law. Both elevators are commanded to the same position based on this consolidated column position and the other feedback signals that make up the control algorithm.