Once again I learn something new.
Quote FCOM-27-20-10-20 HIGH AOA PROTECTION
"To deactivate the angle of attack protection, the pilot must push the sidestick:‐Greater than 8 ° forward, or,‐Greater than 0.5 °for at least 0.5 s when α < α MAX. In addition, below 200 ft, the angle of attack protection is also deactivated, when:‐Sidestick deflection is less than half nose-up, and‐Actual α is less than α prot – 2 °.
Note: 1.At takeoff α prot is equal to α MAX for 5 s.
Note 2.αfloor is activated through the A/THR system, when:‐α is greater than αfloor (9.5 ° in configuration 0; 15 ° in configuration 1, 2; 14 ° in configuration 3; 13 ° in configuration FULL) or‐Sidestick deflection is greater than 14 ° nose up, with either the pitch attitude or the angle-of-attack protection active.
The αfloor function is available from lift-off to 100 ft RA before landing."