It won't stall - AoA protection has priority over all other protections....
So FCOM says. In the sim it would have stalled, for sure. Why? Because HIGH ANGLE OF ATTACK PROTECTION ASSUMES RELIABLE SPEED INDICATIONS. It all occurs at the PFD speeds (black and amber pole and the red pole) V alpha prot, V alpha Max and V alpha floor all exist at the BOTTOM of the speed scale and this is an over speed situation. Though it's an alpha protection, it's triggered by FAC calculated speeds based upon current weight and configuration. The aircraft never gets close to stalling on the PFD! Get 2 ADRs off and get it into alternate law very quickly or stall.