Eeep, very true Spanner_Turner!
Spring force opens the valve. When the airplane starts to
pressurize, airflow through the valve increases. The valve
closes when the airflow through the valve is more than 30 lbs/
min (14 kg/min). When the valve is closed, 1 psi differential
pressure keeps the valve closed.