Tyro
I am talking about your following sentence:
If for some (unknown) reason the start valve does not open when you expect a starter-assist, then the MAN START pb should open it.
This is not correct. Failed start valve cannot be opened in flight. Even in dual engine flame out you only attempt auto starts.