B737 Loss Of All Generators
If you loose ALL generators you have to land on battery power within 30 minutes (or 45 if with the APU battery on the -500).
Actually, flaps are available for landing since the lever acts mechanically.
But there will be no flaps indication on battery only, thus no asymmetry protection.
I would use normal flaps anyway.