The time for the T/R sleeves to translate open using standby hydraulics is required to be 5 seconds or less. Stowing has to be 8 seconds or less. This compares with 3 to open and 5 seconds to retract during normal ops. These times are for one eng. at a time as they are part of a maintenance test procedure.