From FCOM for CFM


Dry crank the engine for 30 s. The start valve automatically reopens when N2 is below 20 %. After the starter cools, and for any subsequent attempt to start the engine, the flight crew must perform a manual engine, or must report the “no start condition” to maintenance for appropriate action.