I agree...in case of double BMC fault the valves will be still opened and will still supply packs etc so no issues regarding pressurization ot other systems problems.the only thing you loose in that scenarioare the warnings associated to the BMC (overpressure overtemperature etc) on ecam so that's why u have to keep monitoring the SD during the flight.