PPRuNe Forums - View Single Post - EFIS & A/C data buses
View Single Post
Old 12th April 2003 | 15:48
  #6 (permalink)  
spannersatcx
25 Anniversary
 
Joined: Dec 1998
Posts: 3,038
Likes: 52
From: .
Cool

If ILS is working correctly then you would get LOC and G/S pointers as normal.

If you then had NCD (non computed data) the LOC and G/S pointers would be removed and freq/ident would be removed but still have the deviation scale.

If you had invalid data the pointers and scale would be removed and you would have a flag, freq/ident would be removed.

And status msg's.

If the input had failed you would get something like the above.

If you lost the Display controller then I would guess that you wouldn't get the flags displayed?

Does that sound about right or not??

As said a bit of an ambiguous question!