On the -400 the actuator drives a quadrant which has cables connected to the ram air door via another quadrant and push rods , and also directly to the louvres. According to AMM not all a/c have moving louvres! !
Doing a pack zone controller BITE will cause ram air system to operate through a full cycle (if memory serves me correctly - a while since I've done one)