Recently I did the mandatory fuel system check and started the groundrun with about 180kg in the main tank. The transferpumps were switched off and the fuel level in the main tank was still reducing until reaching about 160kg and thereafter the fuel level in the supplytanks was getting lower. In the ASB EC is mentioning this fact to be normal. I do not understand, why the main fuel is reducing without the transferpumps?