Here, the same figures apply. Weather below 300ft and/or 1000m visibility require low minima procedures to be applied, which is observed by using either the HGS or a monitored approach.
The choice depends to a great part on the actual weather: a Monitored approach is limited to Cat II weather or better, while the HGS allows the use of Cat IIIa minima.