It is supposed to be set in function of the separation required. Recommended not shorter than five minutes. Theoretically it can be set between 1 and 4096 seconds (2^12) but RTCA DO-258A/EUROCAE ED-100A limits the minimum interval to 64 seconds. If the controlling ATSU does not specify, the aircraft will default to 304 seconds.