PPRuNe Forums - View Single Post - Agusta AW139
Thread: Agusta AW139
View Single Post
Old 3rd Oct 2013, 08:53
  #1635 (permalink)  
Savoia
 
Join Date: Jun 2010
Location: Milano, Italia
Posts: 2,423
Likes: 0
Received 1 Like on 1 Post
FAA AD: DISCONNECT OF FIPS

We are adopting a new airworthiness directive (AD) for Agusta Model AB139 and AW139 helicopters. This AD requires deactivating the Full Icing Protection System (FIPS) and installing a placard next to the FIPS controller stating that flight into known icing is prohibited. This AD is prompted by a report of a fire in the aft avionics bay and the baggage compartment resulting from an Auto Transformer Rectifier Unit internal circuit overload. These actions are intended to prevent a fire, structural damage, and subsequent loss of control of the helicopter.

This AD becomes effective October 16, 2013
http://www.rotor.com/rotornews/Oct13/2013-15-01.pdf
Savoia is offline