Yes, the 320 can be taxied with #1 shut down. As long as the PTU is functioning there is no problem. I've done it.
Be aware though... the moment the second fuel switch goes to cut-off you've lost nw steering, regardless of residual pressure -unlike the old 37's which you could coast while still steering with both shut down.