PPRuNe Forums - View Single Post - FAA Grounds 787s
View Single Post
Old 17th March 2013 | 18:28
  #1308 (permalink)  
RetiredF4
15 Anniversary
 
Joined: Jun 2009
Posts: 801
Likes: 74
From: Germany
Probable cause

If deep discharge in one cell was the beginning of the thermal runaway of one cell, what was then the cause of this rapid deep discharge? Could the modifications in the box ---- better isolations of the cells itself and between the cells, of the wires, and the moisture draining capability ------- point to a moisture and isolation problem of the old box?
condensation causing a short between the box and one cell (remember the contact of one celll completely gone at the ANA event)? In such an event the evidence would evaporate due to the heat and no trace be left.
The new sealed box could prevent such an event by being airtight until a defined overpressure opens the new vents.

Last edited by RetiredF4; 17th March 2013 at 22:25.