PPRuNe Forums - View Single Post - 787 Batteries and Chargers - Part 1
View Single Post
Old 31st Jan 2013, 12:00
  #336 (permalink)  
syseng68k
 
Join Date: Jun 2009
Location: Oxford, England
Posts: 297
Received 0 Likes on 0 Posts
saptzae:
Seriously, it should be possible to use the inverter powered starter,
reprogrammed to support it after shutdown, at very low speed (5-10%),
to ventilate for a few minutes.
Good idea, the starter / generator is inverter driven, so may only need a software
change to implement that.

Not a new idea either: 1994 and maybe earlier Audis had a small run on water pump to keep coolant
circulating around the turbo to prevent heat soak damage...

Regards,

Chris

Last edited by syseng68k; 31st Jan 2013 at 13:47.
syseng68k is offline