PPRuNe Forums - View Single Post - Another 787 electrical/smoke incident (on ground)
Old 9th Jan 2013, 06:20
  #70 (permalink)  
DaveReidUK
 
Join Date: Jan 2008
Location: Reading, UK
Posts: 15,822
Received 206 Likes on 94 Posts
Latest NTSB press release:

Initial investigative findings include:

• The NTSB investigator on scene found that the auxiliary power unit battery had severe fire damage. Thermal damage to the surrounding structure and components is confined to the area immediately near the APU battery rack (within about 20 inches) in the aft electronics bay.

• Preliminary reports from Japan Airlines representatives indicate that airplane maintenance and cleaning personnel were on the airplane with the APU in operation just prior to the detection of smoke in the cabin and that Boston Logan Airport Rescue and Fire Fighting were contacted.

• Rescue and fire personnel and equipment responded to the airplane and detected a fire in the electronics and equipment bay near the APU battery box. Initial reports indicate that the fire was extinguished about 40 minutes after arrival of the first rescue and fire personnel. One firefighter received minor injuries.

Further investigative updates will be issued as events warrant. To be alerted to any updates or developments, please follow the NTSB on T.witter at t.witter.com/ntsb.