Originally Posted by
HazelNuts39
As I understand the C* control law:
C* = q + a*nz, where q = pitch rate, nz = incremental loadfactor, and a determines the 'blend' between nz and q feedback.
For side stick neutral C* = 0, hence q = -a*nz
OK, thanks. I really should have paid more attention in math classes, back then.
Would that make the Alternate law stick free behavior different from that of the Normal law? q limits is different, yes, but?