Beeline,
Thanks for input but still disagree.
FCOm pro - Abn - LGCIU 1 & 2 fault..
Level 2 info.. "normal landing gear control and position indications are lost. LDG GEAR lights on LDG GEAR control panel remain available if LGCIU 1 is electrically supplies".
QRH 32.03 L/G Gravity Extension
Note 2: "in event of gravity extension caused by failure of both LGCius, landing gear position indications on ECAM are lost. LDG GEAR light on LDG GEAR control panel remain available if LGCIU1 electrically supplies"