Can we conclude that Vs1g computation was available, and therefore VLS was computed and displayed?
I would say YES, but
VLS information is somewhat conflicting and at least not clear.
FMGEC supplies GW/Cg to FCPC for calculation of Vs1G, FCPC returns this to FMGEC for VLS calculation.
FMGEC was ready to calculate VLS but was FCPC - in ALT 2 Latched -able to produce Vs1G?
BUSS (NOT on F-GZCP!) when 3 ADR switched off & FCPC revert to ALT (x) latched) is based upon VLS so why not when 2 ADRs/FMGECs returned...
I need some time to sort this out.